Impact of prandial status on the comparison of capillary glucose meter and venous plasma glucose measurements in healthy volunteers

Akhilesh Swaminathan [et.al] - Nama Orang;

Background: There is a negative glucose gradient between the capillary and venous systems, produced by glucose uptake into peripheral tissues. This gradient is augmented by oral glucose ingestion in healthy volunteers; thus prandial status may impact on capillary glucose meter performance. Our primary aim was to investigate whether the (capillary–venous plasma) glucose difference changed in relation to prandial status, in healthy volunteers. Methods: Glucose was measured fasting and also one hour after an ad libitum breakfast, in 103 healthy volunteers. Duplicate capillary (finger stick) measurements were undertaken at both time points, using both the FreeStyle Lite and AccuChek
Performa meters. Simultaneous venous (antecubital fossa) samples were centrifuged immediately after collection and plasma glucose was measured using the laboratory hexokinase method. Results were compared by Bland–Altman difference analysis. Results: The mean (95% CI) pre- and postprandial (capillary–plasma) glucose differences (mmol/L) were calculated for each meter. For the Freestyle Lite, the preprandial difference was 20.51 (20.58 to 20.45) and postprandial difference was 0.81
(0.69–0.94). Corresponding differences for the Performa were 20.13 (20.20 to 20.06) and 1.19 (1.07–1.31), respectively. T-test comparison of participants’ paired pre- and postprandial (capillary–plasma) glucose differences confirmed a significant meal-related change in glucose estimation for both meters (P, 0.0001). Also, both meters read highest at lower glucose concentrations. Conclusions: In healthy volunteers, both glucose meters showed a systematic positive bias one hour after breakfast. The significance of this finding in diabetes remains to be determined.


Ketersediaan

Tidak ada salinan data

Informasi Detail
Judul Seri
Annals of Clinical Biochemistry
No. Panggil
-
Penerbit
: SAGE Publications Ltd., 2013
Deskripsi Fisik
Annals of Clinical Biochemistry 2013; 50: 6–12
Bahasa
English
ISBN/ISSN
-
Klasifikasi
-
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
-
Subjek
BIOKIMIA
Info Detail Spesifik
-
Pernyataan Tanggungjawab
hasnidar/agus
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • Impact of prandial status on the comparison of capillary glucose meter and venous plasma glucose measurements in healthy volunteers
Komentar

Anda harus masuk sebelum memberikan komentar

Elibrary Perpustakaan Universitas Riau
  • Informasi
  • Layanan
  • Pustakawan
  • Area Anggota

Tentang Kami

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Donasi untuk SLiMS Kontribusi untuk SLiMS?

© 2025 — Senayan Developer Community

Ditenagai oleh SLiMS
Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik
Kemana ingin Anda bagikan?