Elibrary Perpustakaan Universitas Riau

Ebook, artikel jurnal dan artikel ilmiah

  • Beranda
  • Informasi
  • Berita
  • Bantuan
  • Pustakawan
  • Area Anggota
  • Pilih Bahasa :
    Bahasa Arab Bahasa Bengal Bahasa Brazil Portugis Bahasa Inggris Bahasa Spanyol Bahasa Jerman Bahasa Indonesia Bahasa Jepang Bahasa Melayu Bahasa Persia Bahasa Rusia Bahasa Thailand Bahasa Turki Bahasa Urdu

Pencarian berdasarkan :

SEMUA Pengarang Subjek ISBN/ISSN Pencarian Spesifik

Pencarian terakhir:

{{tmpObj[k].text}}
No image available for this title
Penanda Bagikan

e-journal

Interference of ethylene glycol with L-lactate measurement is assay-dependent

Andrei Tintu - Nama Orang; Ellen Rouwet - Nama Orang; Henk Russcher - Nama Orang;

Background: Metabolites of ethylene glycol (EG) can cross-react in L-lactate assays, leading to falsely elevated serum lactate levels in case of EG intoxication. In this study, we evaluated the effects of EG and its metabolites on routinely used lactate measuring methods. Methods: Serum aliquots were spiked with either L-lactate, EG or one of its metabolites (all 12.5 mmol/L): glyoxal, glycolate, glyoxylic acid or oxalate. An unspiked sample (L-lactate 2.6 mmol/L) served as a control. L-Lactate levels in these samples were measured in 31 national hospitals on 20 different analysers from nine manufacturers. Results: The L-lactate concentrations in the control sample and in the samples spiked with L-lactate, EG, glyoxal and oxalate provided correct results by all routinely used methods. However, the glycolate and glyoxylic acid spiked samples resulted in falsely elevated L-lactate concentration with all blood gas methods and with the majority of general chemistry methods using L-lactate oxidase. Conclusion: The EG metabolites glycolate and glyoxylic acid were shown to falsely elevate L-lactate results with most of the currently used methods due to cross-reactivity with the oxidase enzyme. Falsely elevated L-lactate results can lead to misdiagnosis and inappropriate management of patients with EG intoxication.


Ketersediaan

Tidak ada salinan data

Informasi Detail
Judul Seri
Annals of Clinical Biochemistry
No. Panggil
-
Penerbit
: SAGE Publications Ltd., 2013
Deskripsi Fisik
Annals of Clinical Biochemistry 2013; 50: 70–72
Bahasa
English
ISBN/ISSN
-
Klasifikasi
-
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
-
Subjek
BIOKIMIA
Info Detail Spesifik
-
Pernyataan Tanggungjawab
hasnidar/agus
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • Interference of ethylene glycol with L-lactate measurement is assay-dependent
Komentar

Anda harus masuk sebelum memberikan komentar

Elibrary Perpustakaan Universitas Riau
  • Informasi
  • Layanan
  • Pustakawan
  • Area Anggota

Tentang Kami

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Donasi untuk SLiMS Kontribusi untuk SLiMS?

© 2025 — Senayan Developer Community

Ditenagai oleh SLiMS
Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik
Kemana ingin Anda bagikan?