Elibrary Perpustakaan Universitas Riau

Ebook, artikel jurnal dan artikel ilmiah

  • Beranda
  • Informasi
  • Berita
  • Bantuan
  • Pustakawan
  • Area Anggota
  • Pilih Bahasa :
    Bahasa Arab Bahasa Bengal Bahasa Brazil Portugis Bahasa Inggris Bahasa Spanyol Bahasa Jerman Bahasa Indonesia Bahasa Jepang Bahasa Melayu Bahasa Persia Bahasa Rusia Bahasa Thailand Bahasa Turki Bahasa Urdu

Pencarian berdasarkan :

SEMUA Pengarang Subjek ISBN/ISSN Pencarian Spesifik

Pencarian terakhir:

{{tmpObj[k].text}}
Image of Performance evaluation of multi-stage open-loop impedance pump
Penanda Bagikan

e-journal

Performance evaluation of multi-stage open-loop impedance pump

V. C. C. Lee - Nama Orang; Y. A. Abakr - Nama Orang; K. C. Woo - Nama Orang;

Abstract
Background: Impedance pump is a simple valveless pumping mechanism, which transports fluid through the mismatch of impedance in the system. Mismatch in impedance occurs when an asymmetrical periodic excitation is
exerted on the elastic tube. Periodic asymmetrical excitation will then produce a unidirectional flow. Considering a
multi-stage system with a single and constant power source, it is well expected that there would be pumping limitation to which the enhancement can reach.
Methods: A multi-stage open-loop impedance pump is developed in the current work. The current work experimentally analyzes and evaluates the pumping performance of a multi-stage open-loop impedance pump, with emphasis on the flow rates induced and pumping limitation. Analyses of flow rates, pressure head and excitation frequencies are performed in its non-dimensional form.
Results: Taking a single-stage system as benchmark, enhancement of 35 and 33.3% is shown in the flow rate and pressure head respectively for a two-stage system. Enhancement of 110 and 60% is shown in flow rate and pressure head of a three-stage system in comparison to the single-stage system. For four-stage system, however, only 27 and 46.7% increments are demonstrated in the flow rate and pressure head, respectively.
Conclusions: The implementation of multi-stage system with single constant power input is demonstrated to be limited only to the three-stage system where the declined pumping performance is exhibited in a four-stage system.
Keywords: Valveless, Multi-stage, Impedance pump, Performance evaluation, Limitation


Ketersediaan

Tidak ada salinan data

Informasi Detail
Judul Seri
-
No. Panggil
-
Penerbit
: Springer Singapore., 2017
Deskripsi Fisik
-
Bahasa
English
ISBN/ISSN
2198-2791
Klasifikasi
NONE
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
International Journal of Mechanical and Materials
Subjek
TEKNIK MESIN
MEKANIKA TEKNIK
Info Detail Spesifik
-
Pernyataan Tanggungjawab
ety
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • Performance evaluation of multi-stage open-loop impedance pump
Komentar

Anda harus masuk sebelum memberikan komentar

Elibrary Perpustakaan Universitas Riau
  • Informasi
  • Layanan
  • Pustakawan
  • Area Anggota

Tentang Kami

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Donasi untuk SLiMS Kontribusi untuk SLiMS?

© 2025 — Senayan Developer Community

Ditenagai oleh SLiMS
Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik
Kemana ingin Anda bagikan?