This study evaluated the inactivation of Brucella suis, Burkholderia pseudomallei, Francisella tularensis, and Yersinia pestis on glass, Hypalon® rubber glove, and stainless steel using vaporous hydrogen peroxide fumigation of a ~15 m3 chamber. A suspension of approximately 1 x 108 colony forming units (CFU) of each organism was dried on coupons of each type of test surface and exposed to va…